Item | Specifications | Unit | Notes | |
4.01 | Module’s Dimensions | 150*15*12 | mm | Bottom conduction cooling |
HSP-①-②-③-④-⑤-⑥/⑦-⑧/⑧-⑨ | ||
①:Port combination | ②:Signal propagation direction | ③:Pump fiber type S-Single clad,D-DCF |
61 - (6+1) ×1 |
Z - Forward F – Backward |
SM04 - 200/220 MMF, 0.22NA SM05 - 220/242 MMF, 0.22NA DM04 - 200/220 MMF, 0.22NA DM05 - 220/242 MMF, 0.22NA ect. |
④:Signal input fiber type | ⑤:Signal output fiber type | ⑥:Pump power per port |
D12 - 20/400 DCF, 0.06NA D13 - 25/400 DCF, 0.06NA D14 - 30/400 DCF, 0.06NA ect. |
D06 – 20/250 DCF, 0.06NA D07 – 25/250 DCF, 0.06NA D08 – 30/250 DCF, 0.06NA ect. |
200 - 200W 400 - 400W 600 - 600W ect. |
⑦:Handling signal power | ⑧/⑧:Input/Output fiber length | ⑨:Package type |
2KW - 2000W 3KW - 3000W 5KW - 5000W ect. |
1.5-1.5m Default 2.0-2.0m ect. |
A1 = Aluminum package 150*15*12mm |
For example:SPC-61-F-SM05-D12-D06-400/2KW-2.0/2.0-A1 |